All products
SV EDGE 4.2K

inverter

SV EDGE 4.2K

4.2 kW · 24V

The SV EDGE 4.2K is the hybrid of the 24 V range: alongside standard off-grid operation it is grid-connect capable, feeding excess solar into the grid at 98% efficiency with a power factor above 0.99 — or running zero-export where feed-in is not permitted.

With 4.2 kW continuous output, a 120 A charger and up to 5,000 W of PV input, it suits a larger villa or small office that wants maximum solar self-consumption with battery backup as the second layer.

Pricing on request — reply usually within the hour, Dubai time.

Specifications

Output
Pure sine wave · 220/230/240VAC ±5%
MPPT range
60–500VDC
Peak power
8000VA
Rated power
4200W
Max PV input
5000W
Grid-connected
170–265VAC · 17.4A · PF>0.99 · eff. 98%
Battery voltage
24VDC
Max charge current
120A

Fitted right, first time

Professional installation

Request installation support

Site preparation

  • Mount indoors or under shade in a dry, ventilated space — keep at least 300 mm clearance on all sides for airflow and service access.
  • Fix to a solid masonry wall or rigid frame at eye level; never on plasterboard alone.
  • Provision a DC battery breaker or fuse rated ~1.25× the maximum charge/discharge current (120 A), plus a PV string isolator and an AC output breaker.
  • Keep battery cable runs short (under 3 m where possible) and use correctly sized lugs — voltage drop on the battery side is the most common cause of nuisance shutdowns.

Safety first

  • This is a 24 V battery-bus system — only connect a battery bank of matching nominal voltage.
  • PV strings carry lethal DC voltage in daylight. Never connect or disconnect PV connectors under load.
  • Torque all terminals to specification and re-check after the first week of operation — thermal cycling loosens DC lugs.
  • Installation must be carried out by a qualified electrician in accordance with local wiring regulations.

Commissioning checklist

  • Confirm battery voltage, PV string Voc and AC input readings on the display match your meter.
  • Verify charge current settings match the battery manufacturer's limits.
  • Simulate a grid failure and confirm the transfer to battery is clean under a real load.
  • Record serial number and settings — Sole Verde support will ask for both.

Installation sequence

  1. 1

    Mount the unit

    Mark the bracket, drill and anchor, then hang and lock the inverter. Confirm it sits plumb and the fans are unobstructed.

  2. 2

    Connect the battery bank

    Use two SV 12-200 AGM batteries in series for the 24 V bank, or a 24 V lithium pack with BMS communication. Connect through the DC breaker with the breaker open, observing polarity — reverse polarity is the single most damaging installation error.

  3. 3

    Connect the PV array

    Up to 5,000 W of PV through the 60–500 VDC MPPT window. Verify string open-circuit voltage with a multimeter before plugging in — it must sit inside the MPPT window at the coldest expected morning.

  4. 4

    Wire the AC side

    Land grid/generator input and load output on separate breakers with correct phase, neutral and earth. Bond the chassis earth terminal to the building earth.

  5. 5

    Grid-connection settings

    If exporting to the grid, set the grid standard and export limit in the menu to match the local utility's requirements — grid feed-in requires utility approval in most markets.

  6. 6

    Power up in sequence

    Close battery DC first, then PV, then AC. Set battery type, charge current and output priority in the menu before applying load.

This guide is a professional summary, not a substitute for the installation manual. Sole Verde supports certified installers across the region — ask us to connect you with one in your market.

Engineered together

Pairs with