All products
SV PRO 11

inverter

SV PRO 11

11 kW · 48V

The SV PRO 11 is the commercial flagship of the line: 11 kW of continuous output from a single wall-mounted unit, engineered from the ground up to run in parallel stacks powering factories, cold storage, fuel stations and large facilities.

It carries the full monitoring stack — WiFi plus RS485/Modbus for integration into building management systems — charges AGM, gel and LiFePO4, and shares the field record of the 48 V platform across Mali, South Sudan, DR Congo and Eritrea.

Pricing on request — reply usually within the hour, Dubai time.

Specifications

Output
Pure sine wave
Parallel
Parallel-capable commercial stacks
Monitoring
WiFi · RS485 / Modbus
Chemistries
AGM · Gel · LiFePO4
PV charging
MPPT
Rated power
11000W
Field record
Mali 500kWp · Juba 480kWp · DR Congo 320kWp · Eritrea 80kWp
System voltage
48VDC

Fitted right, first time

Professional installation

Request installation support

Site preparation

  • Mount indoors or under shade in a dry, ventilated space — keep at least 300 mm clearance on all sides for airflow and service access.
  • Fix to a solid masonry wall or rigid frame at eye level; never on plasterboard alone.
  • Provision a DC battery breaker or fuse rated ~1.25× the maximum charge/discharge current (100 A+), plus a PV string isolator and an AC output breaker.
  • Keep battery cable runs short (under 3 m where possible) and use correctly sized lugs — voltage drop on the battery side is the most common cause of nuisance shutdowns.

Safety first

  • This is a 48 V battery-bus system — only connect a battery bank of matching nominal voltage.
  • PV strings carry lethal DC voltage in daylight. Never connect or disconnect PV connectors under load.
  • Torque all terminals to specification and re-check after the first week of operation — thermal cycling loosens DC lugs.
  • Installation must be carried out by a qualified electrician in accordance with local wiring regulations.

Commissioning checklist

  • Confirm battery voltage, PV string Voc and AC input readings on the display match your meter.
  • Verify charge current settings match the battery manufacturer's limits.
  • Simulate a grid failure and confirm the transfer to battery is clean under a real load.
  • Record serial number and settings — Sole Verde support will ask for both.

Installation sequence

  1. 1

    Mount the unit

    Mark the bracket, drill and anchor, then hang and lock the inverter. Confirm it sits plumb and the fans are unobstructed.

  2. 2

    Connect the battery bank

    Pair with Lithium Battery 11.8KWH modules — its 200 A continuous discharge matches the PRO 11's draw; parallel modules to reach the required autonomy. Connect through the DC breaker with the breaker open, observing polarity — reverse polarity is the single most damaging installation error.

  3. 3

    Connect the PV array

    Size PV per unit with the simulator and balance strings across MPPT inputs. Verify string open-circuit voltage with a multimeter before plugging in — it must sit inside the MPPT window at the coldest expected morning.

  4. 4

    Wire the AC side

    Land grid/generator input and load output on separate breakers with correct phase, neutral and earth. Bond the chassis earth terminal to the building earth.

  5. 5

    Parallel stack configuration

    Mount stack members in a row with equal-length DC cabling to a common busbar, link parallel comms, assign IDs, and commission one unit at a time before enabling the stack.

  6. 6

    BMS / Modbus integration

    For monitored sites, connect RS485 to the facility's Modbus master and register the unit's address map with the BMS integrator.

  7. 7

    Power up in sequence

    Close battery DC first, then PV, then AC. Set battery type, charge current and output priority in the menu before applying load.

This guide is a professional summary, not a substitute for the installation manual. Sole Verde supports certified installers across the region — ask us to connect you with one in your market.

Engineered together

Pairs with